External Check Interface: Table Driven Interface
Use the External Check Interface to import payroll and accounts payable checks information from an external application. The data you load using this adds to the data already stored in PENTA.
The External Check Interface has a Request Type of EXT and an Interface Type of T. Data files you load must have Request Types assigned to the T Interface Type.
This interface updates the check history tables (which feeds the check reconciliation and positive pay processes) without making accounting entries. This allows you to perform a check reconciliation process and generate a positive pay file from within PENTA that is a combination of:
Checks processed in PENTA and
Checks processed by software systems other than PENTA.
If PENTA is unable to load an individual row, it bypasses that record and moves on to the next one. It creates or updates check records using the accepted rows from the file. It notes the rejected rows and does not load them into PENTA.
Limitations & Restrictions
You cannot set up defaults or substitutes for scenarios where there is missing information in the interface data file.
If PENTA rejects a row, you cannot resubmit the file because a record already exists for the file name and file type.
Where to View Loaded Data
You can review and modify interfaced data in the Check Reconciliation report.
If necessary, you can make corrections and/or late entries directly in PENTA. After loading and reviewing, you can use the Cleared Check Entry window to enter additional cleared checks, or remove an external check’s cleared status and process the check.
Available Tables
Check History Record
The following information relates to the INTR_CHK_HIST table.
Column | Entry | Format | Description |
---|---|---|---|
INTR_RQST_ID | Req | C! 13 | The interface request value that you enter to initiate the interface process. The value must be consistent for all records PENTA should process together. |
SEQ_NUM | Req | I 10 | Sequence number uniquely identifying this row within interface request. |
ACTIVITY_CD | Req | C! 1 | Required for all activity. Possible values are:
|
BANK_NUM | Key | C! 9 | The bank with ownership of the bank statement you are clearing. This must be a valid bank number in PENTA. |
BANK_ACCT_NUM | Key | C! 17 | The number of the bank account with ownership of the bank statement you are clearing. This must be a valid account for the bank. |
CHK_NUM | Key | I 8 | Number on the check. |
FORM_ID | Req | C! 8 | Id of the form used to generate the check. The form must be associated with the Bank and Bank Account. |
AMT | Req | F 15.2 | Amount on the check. Must be greater than or equal to 0.00. |
D_CHK_DATE | Req | D | Date on the check. Must be a valid date. |
CHK_HIST_STAT_CD | Req | C! 1 | Id of the check’s status. Possible values:
|
D_CLEAR_DATE | Opt | D | Date the check cleared. Must be a valid date. Required if Check Status is C; otherwise, do not enter a value. |
EMP_ID | Opt | X | Id of the Employee. |
VEN_ID | Opt | X | Id of the Vendor. |
RECORD_NUM | Opt | I 10 | Do not assign this value. PENTA assigns this record number, which you can use to identify records with errors or warning messages. |
USER_ID | Req | C 6 | Id of the employee performing the load process. This user_id must exist in PENTA. |
MODIFICATION_ | Opt | D | Once the process completes, this displays the date PENTA marked the record as modified in the database. The current date is the default value. |